21 |
전기시험 |
유/무선 통신기기
|
(재)대구테크노파크 디지털융합센터
|
ETSI EN 301 908-1:2016
|
IMT cellular networks; Harmonised Standard covering the essential requirements of article 3.2 of the Directive 2014/53/EU; Part 1: Introduction and common requirements
|
(0 ~ 12.75) GHz
|
20 |
전기시험 |
유/무선 통신기기
|
(재)대구테크노파크 디지털융합센터
|
ETSI EN 301 908-1:2019
|
IMT cellular networks; Harmonised Standard for access to radio spectrum; Part1: Introduction and common requirements
|
(0 ~ 12.75) GHz
|
19 |
전기시험 |
유/무선 통신기기
|
(재)대구테크노파크 디지털융합센터
|
ETSI EN 301 908-2: 2015
|
IMT cellular networks; Harmonised EN covering the essential requirements of article 3.2 of the R&TTE Directive; Part 2: CDMA Direct Spread (UTRA FDD) User Equipment (UE)
|
(0 ~ 20) GHz
|
18 |
전기시험 |
유/무선 통신기기
|
(재)대구테크노파크 디지털융합센터
|
ETSI EN 301 908-2:2013
|
IMT cellular networks; Harmonized EN covering the essential requirements of article 3.2 of the R&TTE Directive; Part 2: CDMA Direct Spread (UTRA FDD) User Equipment(UE)
(Exception)
4.2.2.2 Limits: Operating Band XV, XVI
4.2.4.2 Limits: Operating Band XV, XVI
4.2.7.2 Limits: Operating Band XV, XVI
4.2.10.2 Limits: Operating Band XV, XVI
|
(800 ~ 2 200) MHz
|
17 |
전기시험 |
유/무선 통신기기
|
(재)대구테크노파크 디지털융합센터
|
ETSI EN 301 908-2:2017
|
IMT cellular networks; Harmonised Standard covering the essential requirements of article 3.2 of the Directive 2014/53/EU; Part 2: CDMA Direct Spread (UTRA FDD) User Equipment (UE)
|
(0 ~ 20) GHz
|
16 |
전기시험 |
유/무선 통신기기
|
(재)대구테크노파크 디지털융합센터
|
ETSI EN 301 908-2:2020
|
IMT cellular networks; Harmonised Standard for access to radio spectrum; Part 2: CDMA Direct Spread (UTRA FDD) User Equipment (UE)
|
(0 ~ 20) GHz
|
15 |
전기시험 |
전자기적합성 |
(재)대구테크노파크 디지털융합센터
|
EPRI TR 102323 Revision 2:2000
|
Guidelines for Electromagnetic Interference Testing of Power Plant Equipment
5-8 Low-Frequency Conducted Susceptibility
5-10 High-Frequency Conducted Susceptibility
5-12 Low-Frequency Radiated Susceptibility
5-14 High-Frequency Radiated Susceptibility
5-18 Low-Frequency Conducted Emissions
5-20 High-Frequency Conducted Emissions
5-22 Low-Frequency Radiated Emissions
5-24 High-Frequency Radiated Emissions
|
5-8: 30 Hz to 50 kHz
5-10: 10 kHz to 200 MHz
5-12: 30 Hz to 100 kHz
5-14: 10 kHz to 10 GHz
5-18: 30 Hz to 10 kHz
5-20: 10 kHz to 10 MHz
5-22: 30 Hz to 100 kHz
5-24: 10 kHz to 10 GHz |
14 |
전기시험 |
전자기적합성 |
(재)대구테크노파크 디지털융합센터
|
EPRI TR 102323 Revision 3:2004
|
Guidelines for Electromagnetic Interference Testing of Power Plant Equipment
5-6 Low-Frequency Conducted Susceptibility
5-8 High-Frequency Conducted Susceptibility
5-10 Low-Frequency Radiated Magnetic Field Susceptibility
5-12 High-Frequency Radiated electric Field Susceptibility
5-19 Low-Frequency Conducted Emissions
5-21 High-Frequency Conducted Emissions
5-23 Low-Frequency Radiated Magnetic Field Emissions
5-24 High-Frequency Radiated Electric Field Emissions
|
5-6: 30 Hz to 50 kHz
5-8: 10 kHz to 200 MHz
5-10: 30 Hz to 100 kHz
5-12: 10 kHz to 10 GHz
5-19: 30 Hz to 10 kHz
5-21: 10 kHz to 10 MHz
5-23: 30 Hz to 100 kHz
5-24: 10 kHz to 10 GHz |
13 |
전기시험 |
전자기적합성 |
(재)대구테크노파크 디지털융합센터
|
MIL-STD-461D:1993
|
REQUIREMENTS FOR THE CONTROL OF ELECTROMAGNETIC INTERFERENCE EMISSIONS AND SUSCEPTIBILITY
5.3.1 CE101, Conducted emissions, power leads, 30 Hz to 10 kHz
5.3.2 CE102, Conducted emissions, power leads, 10 kHz to 10 MHz
5.3.4 CS101, Conducted susceptibility, power leads, 30 Hz to 50 kHz
5.3.9 CS114, Conducted susceptibility, bulk cable injection, 10 kHz to 400 MHz
5.3.10 CS115, Conducted susceptibility, bulk cable injection, impulse excitation
5.3.11 CS116, Conducted susceptibility, damped sinusoidal transients, cables and power leads, 10 kHz to 100 MHz
5.3.12 RE101, Radiated emissions, magnetic field,30 Hz to 100 kHz
5.3.13 RE102, Radiated emissions, electric field, 10 kHz to 18 GHz
5.3.15 RS101, Radiated susceptibility, magnetic field, 30 Hz to 100 kHz
5.3.16 RS103, Radiated susceptibility, electric field, 10 kHz to 40 GHz(Exception: below 100 MHz, 200 V/m)
|
30 Hz to 10 kHz
10 kHz to 10 MHz
30 Hz to 50 kHz
10 kHz to 400 MHz
5 A
10 A, 10 kHz to 100 MHz
30 Hz to 100 kHz
10 kHz to 18 GHz
30 Hz to 100 kHz
10 kHz to 18 GHz |
12 |
전기시험 |
전자기적합성 |
(재)대구테크노파크 디지털융합센터
|
MIL-STD-461E:1999
|
REQUIREMENTS FOR THE CONTROL OF ELECTROMAGNETIC INTERFERENCE CHARACTERISTICS OF SUBSYSTEMS AND EQUIPMENT
5.4 CE101, conducted emissions, power leads, 30 Hz to 10 kHz
5.5 CE102, conducted emissions, power leads, 10 kHz to 10 MHz
5.7 CS101, conducted susceptibility, power leads, 30 Hz to 150 kHz
5.12 CS114, conducted susceptibility, bulk cable injection, 10 kHz to 200 MHz
5.13 CS115, conducted susceptibility, bulk cable injection, impulse excitation
5.14 CS116, conducted susceptibility, damped sinusoidal transients, cables and power leads, 10 kHz to 100 MHz
5.15 RE101, Radiated emissions, magnetic field, 30 Hz to 100 kHz
5.16 RE102, radiated emissions, electric field, 10 kHz to 18 GHz
5.18 RS101, radiated susceptibility, magnetic field, 30 Hz to 100 kHz
5.19 RS103, radiated susceptibility, electric field, 2 MHz to 40 GHz(Exception: below 100 MHz, 200 V/m)
|
30 Hz to 10 kHz
10 kHz to 10 MHz
30 Hz to 150 kHz
10 kHz to 200 MHz
5 A
10 A, 10 kHz to 100 MHz
30 Hz to 100 kHz
10 kHz to 18 GHz
30 Hz to 100 kHz
10 kHz to 18 GHz |