11 |
전기시험 |
전자기적합성 |
(재)대구테크노파크 디지털융합센터
|
MIL-STD-461F:2007
|
REQUIREMENTS FOR THE CONTROL OF ELECTROMAGNETIC INTERFERENCE CHARACTERISTICS OF SUBSYSTEMS AND EQUIPMENT
5.4 CE101, conducted emissions, power leads, 30 Hz to 10 kHz
5.5 CE102, conducted emissions, power leads, 10 kHz to 10 MHz
5.7 CS101, conducted susceptibility, power leads, 30 Hz to 150kHz
5.11 CS106, conducted susceptibility, transients, power leads
5.13 CS114, conducted susceptibility, bulk cable injection,10 kHz to 200 MHz
5.14 CS115, Conducted susceptibility, bulk cable injection, impulse excitation
5.15 CS116, conducted susceptibility, damped sinusoidal transients, cables and power leads, 10 kHz to 100 MHz
5.16 RE101, radiated emissions, magnetic field, 30 Hz to 100 kHz
5.17 RE102, radiated emissions, electric field, 10 kHz to 18 GHz
5.19 RS101, radiated susceptibility, magnetic field, 30 Hz to 100 kHz
5.20 RS103, radiated susceptibility, electric field, 2 MHz to 40 GHz
(Exception: below 100 MHz, 200 V/m)
|
30 Hz to 10 kHz
10 kHz to 10 MHz
30 Hz to 150 kHz
400 V
10 kHz to 200 MHz
5 A
10 A, 10 kHz to 100 MHz
30 Hz to 100 kHz
10 kHz to 18 GHz
30 Hz to 100 kHz
10 kHz to 18 GHz |
10 |
전기시험 |
전자기적합성 |
(재)대구테크노파크 디지털융합센터
|
MIL-STD-461G:2015
|
REQUIREMENTS FOR THE CONTROL OF ELECTROMAGNETIC INTERFERENCE CHARACTERISTICS OF SUBSYSTEM SAND EQUIPMENT
5.4 CE101, conducted emissions, audio frequency currents, power leads
5.5 CE102, conducted emissions, radio frequency potential, power leads
5.7 CS101, conducted susceptibility, power leads
5.12 CS114, conducted susceptibility, bulk cable injection
5.13 CS115, conducted susceptibility, bulk cable injection, impulse excitation
5.14 CS116, conducted susceptibility, damped sinusoidal transients, cables and power leads
5.16 CS118, personnel borne electrostatic discharge
5.17 RE101, radiated emissions, magnetic field
5.18 RE102, radiated emissions, electric field
5.20 RS101, radiated susceptibility, magnetic field
5.21 RS103, radiated susceptibility, electric field
(Exception: below 100 MHz, 200 V/m)
|
30 Hz to 10 kHz
10 kHz to 10 MHz
30 Hz to 150 kHz
10 kHz to 200 MHz
5 A
10 A,10 kHz to 100 MHz
±15 kV(Air), ±8 kV(Contact)
30 Hz to 100 kHz
10 kHz to 18 GHz
30 Hz to 100 kHz
10 kHz to 18 GHz |
9 |
전기시험 |
전자기적합성 |
(재)대구테크노파크 디지털융합센터
|
MIL-STD-462D:1993
|
MEASUREMENT OF ELECTROMAGNETIC INTERFERENCE CHARACTERISTICS
5. CE101, CONDUCTED EMISSIONS, POWER LEADS, 30 Hz TO 10 kHz
5. CE102, CONDUCTED EMISSIONS, POWER LEADS, 10 kHz TO 10 MHz
5. CS101, CONDUCTED SUSCEPTIBILITY, POWER LEADS, 30 Hz TO 50 kHz
5. CS114, CONDUCTED SUSCEPTIBILITY, BULK CABLE INJECTION, 10 kHz TO 400 MHz
5. CS115, CONDUCTED SUSCEPTIBILITY, BULK CABLE INJECTION, IMPULSE EXCITATION
5. CS116, CONDUCTED SUSCEPTIBILITY, DAMPED SINUSOIDAL TRANSIENTS, CABLES AND POWER LEADS, 10 kHz TO 100 MHz
5. RE101, RADIATED EMISSIONS, MAGNETIC FIELD, 30 Hz TO 100 kHz
5. RE102, RADIATED EMISSIONS, ELECTRIC FIELD, 10 kHz TO 18 GHz
5. RS101, RADIATED SUSCEPTIBILITY, MAGNETIC FIELD, 30 Hz TO 100 kHz
5. RS103, RADIATED SUSCEPTIBILITY, ELECTRIC FIELD, 10 kHz TO 40 GHz
(Exception: below 100MHz, 200 V/m)
|
30 Hz to 10 kHz
10 kHz to 10MHz
30Hz to 50 kHz
10kHz to 400 MHz
5A
10A, 10 kHz to 100 MHz
30 Hz to 100 kHz
10 kHz to 18 GHz
30 Hz to 100 kHz
10 kHz to 18 GHz |
8 |
전기시험 |
전자기적합성 |
(재)대구테크노파크 디지털융합센터
|
REGULATORY GUIDE 1.180 Revision 1:2003
|
GUIDANCE FOR EVALUATING ELECTROMAGNETIC AND RADIO-FREQUENCY INTERFERENCE IN SAFETY-RELATED INSTRUMENTATION AND CONTROL SYSTEMS
3.1 CE101-Conducted Emissions, Low Frequency
3.2 CE102-Conducted Emissions, High Frequency
3.3 RE101-Radiated Emissions, Magnetic Field
3.4 RE102-Radiated Emissions, Electric Field
4.1.1 CS101-Conducted Susceptibility, Low Frequency
4.1.2 CS114-Conducted Susceptibility, High Frequency
4.2 EMI/RFI Conducted Susceptibility Testing- Signal Leads
4.3.1 RS101-Radiated susceptibility, Magnetic Fields
4.3.2 RS103-Radiated susceptibility, Electric Fields
|
3.1 CE101: 30 Hz to 10 kHz
3.2 CE102: 10 kHz to 2 MHz
3.3 RE101: 30 Hz to 100 kHz
3.4 RE102: 2 MHz to 10 GHz
4.1.1 CS101: 30 Hz to 150 kHz
4.1.2 CS114: 10 kHz to 30 MHz
4.2 EMI/RFI-Signal Leads10 kHz to 30 MHz for CS114,
2 A for CS115,
5 A for CS116
4.3.1 RS101: 30 Hz to 100 kHz
4.3.2 RS103: 30 MHz to 10 GHz |
7 |
전기시험 |
전자기적합성 |
(재)대구테크노파크 디지털융합센터
|
REGULATORY GUIDE 1.180:2000
|
GUIDANCE FOR EVALUATING ELECTROMAGNETIC AND RADIO-FREQUENCY INTERFERENCE IN SAFETY-RELATED INSTRUMENTATION AND CONTROL SYSTEMS
4.1 CE101-Conducted emissions, Low Frequency
4.2 CE102-Conducted emissions, High Frequency
4.3 CS101-Conducted susceptibility, Low Frequency
4.4 CS114-Conducted susceptibility, High Frequency
4.5 RE101-Radiated emissions, Magnetic field
4.6 RE102-Radiated emissions, Electric field
4.7 RS101-Radiated susceptibility, Magnetic Fields
4.8 RS103-Radiated susceptibility, Electric Fields
|
4.1 CE101: 30 Hz to 10 kHz
4.2 CE102: 10 kHz to 10 MHz
4.3 CS101: 30 Hz to 50 kHz
4.4 CS114: 10 kHz to 400 MHz
4.5 RE101: 30 Hz to 100 kHz
4.6 RE102: 10 kHz to 1 GHz
4.7 RS101: 30 Hz to 100 kHz
4.8 RS103: 10 kHz to 1GHz |
6 |
전기시험 |
소프트웨어
|
(재)대구디지털산업진흥원
|
ISO/IEC 25023
|
Systems and software engineering — Systems and software Quality Requirements and Evaluation (SQuaRE) — Measurement of system and software product quality
|
전체
|
5 |
전기시험 |
소프트웨어
|
(재)대구디지털산업진흥원
|
ISO/IEC 25024
|
System and software engineering - system and software Quality Requirements and Evaluation(SQuaRE) - Measurement of data quality
|
전체
|
4 |
전기시험 |
소프트웨어
|
(재)대구디지털산업진흥원
|
ISO/IEC 25051
|
Software engineering — Systems and software Quality Requirements and Evaluation (SQuaRE) — Requirements for quality of Ready to Use Software Product (RUSP) and instructions for testing
|
전체
|
3 |
전기시험 |
소프트웨어
|
(재)대구디지털산업진흥원
|
KS X ISO/IEC 25023
|
시스템 및 소프트웨어 공학 - 공학-소프트웨어 제품 품질 요구사항 및 평가(SQuaRE) - 시스템 및 소프트웨어 제품의 품질 측정
|
전체
|
2 |
전기시험 |
소프트웨어
|
(재)대구디지털산업진흥원
|
KS X ISO/IEC 25051
|
정보기술-소프트웨어 공학-소프트웨어 제품 품질 요구사항 및 평가(SQuaRE)-상업용 패키지(COTS) 소프트웨어 제품에 대한 요구사항 및 테스팅에 대한 지시사항
|
전체
|